2 wire N.O. closing limit switch imput (set parameter
When activated the opening travel ends (XPASS B 800C).
3 wire N.O. closing limit switch imput (set parameter
When activated the opening travel ends (XPASS B 1200C).
FCA
2 wire N.O. opening limit switch imput (set parameter
ends.
3 wire N.O. opening limit switch imput (set parameter
ends (XPASS B 1200C).
STOP
N.C. safety input. When it is activated, the automation is immediately stopped. During the pause time, a stop control eliminates
the automatic closing, leaving the bollard open waiting for a command.
FTC
N.C. photocell input. It allows the automation to be closed only if the safety devices have not triggered. Operating mode
programmable with parameter
CLOSE
N.O. closing input. It allows the automation to be closed only if the safety devices have not triggered. Operating mode pro-
grammable with parameter
OPEN
N.O. opening input.
By keeping this input controlled, the automation performs the opening manoeuvre and will close automatically only when the
input is freed. Connect clocks, daily timers or weekly timers here if wanted.
START
N.O. input that operates the bollard's opening and closing. The command is ignored while opening
PDM
Programmable Input
-3°liv..
May be duplicated on AUX output.
PRES
1
Closure travel limit pressure switch input (see parameter
When activated the closing travel nishes (For hydraulic bollards only).
PRES 2
ECD pressure switch input (see parameter
(For ECD equipped bollards only).
UPS
UPS status input. To be connected to smart UPS with status output, active-high during mains failure. The control unit has also
an internal detector that works with simpler square-wave and quasi-sinusosidal UPS. With these simpler UPS there is no need
to use this input.
AUXILIARY INPUT AUX
For bollards with ECD device. Is active when emergency ECD command is active (see parameter
ANALOG INPUT
Multi-purpose analog input 0..5V
ANTENNA
Antenna connection for the radio receiver (option).
Control unit
J5A/J5B
6.4
INPUTS TERMINAL BLOCK
-level 1.
-level 1.
- level 3 and parameter
- 27 -
- level 3 and parameter
- level 3 and parameter
- level 3). When activated the opening travel
- level 3). When activated the opening travel
- level 3). Limit switch N.C. input in closing.
- level 2).
EN
- level 2).
- level 2).
- level 3)