Single Doors, Communication With Fem; Configuration; Interlock Control (Basic Wiring Required) - Record DFA127 Instructions Manual

Automatic door systems
Hide thumbs Also See for DFA127:
Table of Contents

Advertisement

18.4

2 single doors, communication with FEM 1

If 2 drive units are operated as an interlock it is important that each time only one door is
opened. The other door remains closed until the first door is closed again.
If one door is opened, it will block through the output SAA the other door until it is closed
again.
The actuating signal of the second door is stored and if there is a light, it will signal to the
user that he was recognized, but that the door will open when the other door is closed.
18.5

Configuration

FEM 1
FEM-Type
DOOR SYSTEM
Interlock with FEM 1
18.6

Interlock control (basic wiring required)

Actuation required inside the interlock (or additional wiring for interlock sequence control).
102-127108955
Interlock mode with 2 single-leaf doors
NOTICE
If more than 2 drive units are operated as an interlock function, a super-ordinate
control system is necessary.
M
M
Installation A
Installation B
Basic
Inactive
V1.1
Interlock
All operation mo-
Only One-Way /
des
Locked
18
85/ 102