Record DFA127 Instructions Manual page 75

Automatic door systems
Hide thumbs Also See for DFA127:
Table of Contents

Advertisement

→ Manual locking
→ Disabled
→ Active
→ Start delay
CAN BUS
→ FEM-1
→ AKI 1
→ SI 1
→ AKA 1
→ SA 1
→ SL
→ SR
→ AKI 2
102-127108955
NOTICE
The entrance VAK waits for a maximum of 5 s before the feedback signal from
the electrical door opener before the door opens.
▪ Recommended for doors to be closed manually.
X
Function deactivated
If a feedback contact from the electric door opener provides a
signal to the VAK input, all trip devices are interrupted. In addi-
tion to the current operating mode, the text display of BDE-D
indicates
changed at will with the BDE-D.
▪ Recommended for doors that have no feedback
0
Delay time until door opens after unlocking.
0 = no delay
40 = 8 seconds delay
In this menu all the units identified on the CAN BUS – such as
sensors or extended function modules – are displayed.
0 = no unit present or unit unidentified (disabled)
1 = unit installed and functional (enabled)
? = unit defective or missing
▪ Removed units (?) must be deactivated manually with
0
Extended function module FEM1
▪ 4 configurable inputs
▪ 14 configurable relay outputs
▪ Choice between potential-free normally open contact
▪ All FEM1 outputs can be activated with the available
0
RAD: motion sensor 1 – inside
0
RIC: safety sensor 1 – inside
0
RAD: motion sensor 1 – outside
0
RIC: safety sensor 1 – outside
0
AIR: safety secondary closing edge – left
0
AIR: safety secondary closing edge – right
0
RAD: motion sensor 2 – inside
'Manually locked'
about the operating state.
the FPC902.
(NO) and normally closed contact (NC).
Basic setting: NO contact (jumper)
configurations. Availability depends on the control
unit in use.
V1.1
Configurations
. The operating mode can be
16
75/ 102