Preparation; Connecting The Sensors, Electrical Door Openers; Checking The Settings - Record DFA127 Instructions Manual

Automatic door systems
Hide thumbs Also See for DFA127:
Table of Contents

Advertisement

11.7

Preparation

11.8

Connecting the sensors, electrical door openers

▪ Connect the radar, the optical sensor-strips and the electric door openers (electrical door
openers must have a suppressor diode) with the power switched off.
11.9

Checking the settings

1. Position the jumpers for the required function according to chapter
tions
2. Check the external jumpers for auxiliary units that are not connected, such as EMER-
GENCY STOP, safety sensors SIS and SIO.
102-127108955
NOTICE
Read and pay attention to chapter
The power supply must be fused with max. 10 A.
DANGER
Electric shock
• Electric shock and burns, death if touching the power supply without safety
cover.
 Interrupt the power supply before taking the safety cover off.
 Mount the safety cover before connecting the operator to the power supply
again.
.
NOTICE
Safety sensors SIO/SIS (if present) must be connected and adjusted before the
calibration run..
Installation DFA 127
Safety instructions
1. Interrupt the power supply with the main
switch or power plug.
2. The power supply cable must be con-
nected to the power supply DFA (feed the
cable to the connectors complete with its
sheath).
3. Check the wiring according to general
schematic diagram 102-127109567.
V1.1
!
Operating instruc-
39/ 102
11

Hide quick links:

Advertisement

Table of Contents
loading