6.1 Digital Board Specification (Single Board)

INPUTS
AC VOLTAGE
ACTIVATION 1
- First input to open the door. Instant activation (i.e. push buttons)
(ACT'N1)
- ON = Closed contact to ground/common.
- See Function AA", Setting A1" for description of alternate operation
ACTIVATION 2
- Second input to open the door. Delayed activation.
(ACT'N2)
- ON = Closed contact to ground/common.
- See Function AA", Setting A1" for description of alternate operation.
SAFETY 1
- For Safety1 ON door will not open if presently fully closed and door will not close if presently
- ON = Closed contact to ground/common.
SAFETY 2
- For Safety2 ON and Activation1 input ON door will drive at hold speed. If Activation1 input goes
off door closes. If Safety2 goes off door will open. (i.e. Door mounted sensor on swing side -
Superscan)
- ON = Closed contact to ground/common.
OUTPUTS
MOTOR
- 2 motor connectors to drive door in either clockwise or counter clockwise direction.
_
- Interface with BEA Bodyguard sensor. (replaces LO-21K lockout relay)
DATA
and DATA+
OTHER FEATURES
Adjustable by potentiometer
CLOSING SPEED
BACK CHECK and
1 switch for each
LATCHING
Lockout of door while closing is selectable via Function AA", Setting A2".
LOCKOUT
PUSH AND GO
When Push and Go is selected a manual push of the door will trigger the door to open.
Selectable via Function AA", Setting A3". Default is OFF
OVERLOAD
Selectable Overload setting. Adjustable by potentiometer.
ON/OFF/
Terminal block position to accommodate a 3 way switch for ON, OFF and Hold Open positions.
HOLD OPEN
6.0 DIGITAL BOARD & PROGRAMMING
LINE VOLTAGE
Fully Automatic
120VAC 60Hz
Handicap
Fully Automatic
240VAC 50Hz
Handicap
fully opened (i.e. overhead presence sensors - Bodyguard)
Record Canada Inc.
Toll Free: 1-877-348-6837
info.ditec.ca@recorddoors.com
www.recorddoors.ca
TRANSFORMER (Hammond)
#166N24 – 24VAC – 4AMP
#166M16 – 16VAC – 3AMP
#266N24 – 24VAC – 4AMP
#266M16 - 16VAC – 3AMP
Record USA Inc.
Toll Free: 1-866-901-4284
info.ditec.us@recorddoors.com
www.recorddoors.com
(Updated Nov 2017)
Pg. 45
HA8-SP Manual V. 7.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fa8-sp

Table of Contents