Security Inspection According En 16005; Swing Doorsets; Protection During Opening And Closing Cycles - Record DFA127 Instructions Manual

Automatic door systems
Hide thumbs Also See for DFA127:
Table of Contents

Advertisement

3

Security inspection according EN 16005

Like the german standard DIN 18650, the EN 16005 describes the requirements and the test
methods for the safe use of power-operated pedestrian doors. The EN 16361 describes the
requirements for the production process and towards the documentation / classification of
the doors.
The EN 16005 is valid for automatic sliding, folding, swing and revolving doorsets. It does
not apply to high speed doors (Speedcord).
We recommend that you organize and use your country-specific version of the EN 16005.
3.1

Swing doorsets

Automatical swing doorsets must be provided with extra safety devices.
3.1.1

Protection during opening and closing cycles

The standard EN 16005 stipulates that a person must be detected on both sides of the door
during the closing cycle.
▪ The CA reference body (700 x 300 x 200 mm) must be detected at any point in an area
as wide as the doorway and extending over a distance of 200 mm on both sides of the
door axle.
▪ Devices to protect against the danger of crushing and impact between the door leaf and
the adjacent parts of the surroundings shall be provided during the opening and the clos-
ing cycles.
– presence sensors in the zone to be protected
– sufficient safety distances
– low energy movement
– activation mat
Solution:
Safety devices on the door leaf
Examples:
CEDES TOF/Taxi
102-127108955
Security inspection according EN 16005
BEA 4SAFE ON SW
V1.1
3
14/ 102

Hide quick links:

Advertisement

Table of Contents