→ Locked
→ Closed
INPUT/OUTPUT --> FEM1
→ FEM type
→ Basic
→ Interlock
→ AUX10_IN
→ Disabled
→ S_AUS
102-127108955
The output signal shows whether the door is locked.
Output 0 V = door not locked.
Output 24 V = door closed and locked.
▪ The output is only set correctly for locking by VAK
signal.
This output signal shows whether the door is closed.
Output 0 V = door not closed.
Output 24 V = door closed.
▪ The output may switch with a slight delay, i.e. when
closing only after the pressing phase and, when ope-
ning by hand, not before the door has opened by ap-
prox. 10 mm.
This parameter assigns the configurable input and output sig-
nals of the FEM1 to application-compatible default values.
X
All input and output signals are deactivated.
Configuration for interlock operation.
▪ It is possible to operate the system with sensors be-
tween the doors or without sensors with interlock se-
quential control.
Parameter
Input → AUX10_IN
Input → AUX11_IN
Input → AUX12_IN
Output → AUX10_OUT
Output → AUX11_OUT
Output → AUX12_OUT
Configurable input signal for FEM1
Connector J1, terminals 64 & 65
Floating, optically disconnected 24V input
X
Interlock control disabled.
▪ Both doors open at the same time by activation at
one side. SIS is active and stops the respective door.
V1.1
Configurations
Default value
S_AUS
SEA
SFS_IN
SAA
SAMP
SFS_OUT
16
77/ 102