Record DFA127 Instructions Manual page 72

Automatic door systems
Hide thumbs Also See for DFA127:
Table of Contents

Advertisement

→ Active sensors
→ Disabled
→ SIS disabled
→ SIS enabled
→ SIS enabled AUTO
→ Closing speed
CONTROL UNIT
→ BDE-M
→ 3-position (AUTO)
→ 4-position
102-127108955
X
NOTICE
For the correct operation of "Manual mode with active sensors" the correspond-
ing parameters must be set and the BDE-D or the toggle switch must be set to
'Manual' !
The door can be passed by non-disabled people as a normal manual door; dis-
abled persons may trigger an automatic opening of the door by remote control.
Menu: Manual mode / Active sensors / SIS disabled or SIS enabled
Do not enable 'Manual mode' with assisted closure!
20
X
2)
The sensors for tripping or safety are connected so that their
behaviour can be influenced in 'Manual mode'.
No sensor enabled
All sensors excluding SIS enabled
All sensors including SIS enabled
SIS is only effective upon closing when the door has been
opened automatically.
Variable closing speed that can be situation-influenced.
0 = lowest speed
40 = highest speed
▪ The maximum reachable speed depends on the
spring tension set.
▪ Existing electric door openers must definitely engage.
Selection of the mechanical control unit.
▪ Various functions can be assigned to the side-
mounted BDI 3-position rocker switch.
▪ The BDE-M can only be connected to STG 127 via
the option BDI-M.
▪ Not more than one BDE-M may be connected at a
time.
▪ BDE-D and BDE-M can be operated in parallel, the
operating mode being given priority.
Manual; Automatic; Continuously open
Operating modes:
▪ Function corresponds to the symbols of the three-
position BDI rocker switch on the side cover of the
DFA 127.
Setting for the BDE-M
▪ Appropriate setting for the time switch input (e.g.
SURV
)
BDE2
BDE1
0 V
0 V
V1.1
Configurations
'Locked'
.
Operating mode
'Locked'
16