→ AUX11_IN
→ Disabled
→ SEA
→ AUX12_IN
→ Disabled
→ SFS_IN
→ AUX13_IN
→ Disabled
→ AUX10_OUT ... AUX1D_OUT
→ Inactive
→ Locked
→ Closed
102-127108955
Configurable input signal for FEM1
Connector J1, terminals 66 and 67 (only FEM1)
Floating, optically disconnected 24V input
X
Input signal for synchronisation of an interlock.
'block activation'
▪ The signal
ing as long as the interlock is in use from the other
door. An activation signal is buffered until the inter-
lock is released by the other door. Only then does the
door open.
Configurable input signal for FEM1.
Connector J1, terminals 68 and 69 (only FEM1)
Floating, optically disconnected 24V input
X
Input "interlock sequential control".
▪ Appropriate for interlocks and "draught lobbies" with-
out triggering sensors within the interlock chamber.
▪ The signal must be linked with the output signal
SFS_OUT of the other door. The latter transmits the
triggering signal to the first door.
Configurable input signal for FEM1
Connector J1, terminals 70 and 71 (only FEM1)
Floating, optically disconnected 24V input
X
14 configurable output signals for FEM1.
Connector J2, floating change over contact 30 volt DC / 1 A
Normally closed (NC) or normally open (NO) contact (selection
via jumper position --> basic position = NO contact)
X
This output signal shows whether the door is locked.
Relay passive = door not locked
Relay active = door closed and locked
This output signal shows whether the door is closed.
Relay passive = door not closed
Relay active = door closed
▪ The output may switch with a slight delay, i.e. when
closing only after the pressing phase and, when ope-
ning by hand, not before the door has opened up to
approx. 10 mm.