Description Of Parameters - Record DFA127 Instructions Manual

Automatic door systems
Hide thumbs Also See for DFA127:
Table of Contents

Advertisement

Configurations on the swing door operator can only be made with the electronic BDE-D, the
service- and flashprogrammer FPC 902 or the optional Testbox. If a toggle switch is con-
nected, the BDE-D, service- and flashprogrammer FPC 902 or Testbox must be connected
briefly for the configuration.
Please always leave the configuration review sheet in the drive even when the STG is re-
placed!
16.2

Description of parameters

W = Factory settings: Basic drive (FP)
PARAMETER
DRIVING CYCLE
→ Closing speed
→ Opening speed
→ Acceleration
→ Creep drive
→ Closing force
TIME DELAYS OPEN
→ Time delay open
102-127108955
W
Comment
20
Driving speed when closing the door.
0 = lowest speed
40 = highest speed
▪ The maximum reachable speed depends on the
driven distance (door width) and the acceleration set-
ting.
36
Driving speed of the opening door.
0 = lowest speed
40 = highest speed
▪ The maximum speed reachable depends upon the
opening angle and the acceleration setting.
▪ DIN: > 1.5 s <4 s
▪ Start-up acceleration while opening and closing the
36
door.
0 = low acceleration
40 = heavy acceleration
0
Early braking when closing increases the distance of door
travel with minimal closing speed in the range of the last past
20°.
0 = no creep drive
1 = creep for the last 2.5% of door travel
40 = 100%, i.e. creep for the entire door travel
(e.g. securing the upper shearing edge of the lintel)
36
Increasing the motorised force during closing.
▪ DIN: 0
▪ If the value is higher than 0, a fixed safety sensor
must be installed in the closing direction!
2
Determines the minimum time for which a door stays open
after it has been opened by a type AKA, AKI or automatic trig-
gering signal.
0..20 = 0 to 20 seconds, 1 s increments
V1.1
Configurations
16
61/ 102