→ Brussels Airport
→ Default 1
MASTER/SLAVE 2 LEAVES
→ AKA function
→ Master + Slave
→ Only Master
→ Overlap
102-127108955
Manual drive → When Auto-
matic
Manual drive → Collision
Manual drive → Closing speed 10
Setting for Full Power Applications at Brussels airport.
Parameter
Miscellaneous → Alarm display
→ Time activation
Miscellaneous → Alarm display
→ Time safety
Setting for Full Power Applications in Germany.
Parameter
Manual drive → When Auto-
matic
Manual drive → Assisted clo-
sure
Manual Drive → Active sensors SIS activated
Locking → Lock function
Locking → Lock Manually
Output → AUX1_OUT
This is used to configure the function of AKA input with mas-
ter/slave systems.
▪ In corridors or passages it can be determined
whether only one or both leaves open when trig-
gered, e.g. normal operation acting on one door or
opening both doors when a hospital bed needs to
pass.
X
AKA acts on both drives.
AKA input affects only the master drive, AKI and SSK act on
both drives ("sister-circuit"). No one-way operation is possible.
5
0 = no overlap (blunt door opening)
5 = slight overlap (simple door opening)
40 = very large overlap (multiple door opening)
In the adjusted overlapping area only ever one leaf moves.
When opening, the stationary leaf waits until the moving leaf
has left the overlapping area y.
V1.1
Configurations
Activated
Activated
Default value
0
6
Default value
Activated
Increasing
Always locked
Activated
Test sensors
16