Checking The Leds On The Stg; Checking The Bde Functions And Actuation Devices; Programming Door Speeds And Hold-Open Times; Configuration Of Specific Customer Settings - Record DFA127 Instructions Manual

Automatic door systems
Hide thumbs Also See for DFA127:
Table of Contents

Advertisement

13.4

Checking the LEDs on the STG

Check LED 1...3 according to the table in chapter
13.5

Checking the BDE functions and actuation devices

BDE-position
1. Door must open and remain open
2. Check the movement characteristics
3. Door cannot be moved by hand when open
BDE-position
1. Door must close
2. Check the movement characteristics
3. Check locking if present (see chapter
4. Pressing
5. SSK must release (if present)
6. AKI and AKA must not operate
BDE-position
1. AKI and SSK must operate
2. AKA must not be triggered when the door is closed
13.6

Programming door speeds and hold-open times

The functions are described in chapter
13.7

Configuration of specific customer settings

The possibilities are described in chapter
All modifications must be entered on the configuration sheet.
13.8

Safety check

1. BDE-position
2. Open door (e.g. with AKI)
3. Operate a safety device while closing. Door must re-open.
4. The same check must be performed with every safety device present.
13.9

Checking automatic reverse

1. Obstruct door while closing. The door must reverse. When the door closes the next time
it moves at creep speed past the obstruction point.
2. Obstruct the door while opening. The door stops for hold-open time and closes. When
the door opens the next time it moves at creep speed past the obstruction point.
13.10

Touch control (push to actuate)

See about the configuration in chapter
door-opening will be initiated.
13.11

Checking the functions of the DFA

▪ Check all the DFA functions
▪ Tighten the arm screw
13.12

Hand over to the client

▪ Instruct the client
▪ Hand over the operating manual
▪ RESET demonstration
102-127108955
(permanently open)
(locked)
a second time initiates the SSK opening
(one-way traffic)
(automatic mode)
Commissioning DFA 127
Controls on the STG 127
Status and fault signals BDE-D
Operating instructions
Configurations
.
Configurations
. By pressing lightly on the door, a
V1.1
.
)
.
13
53/ 102

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents