Danfoss VLT AutomationDrive FC 360 Quick Manual page 48

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Specifications
Frequency converter
typical shaft output [kW]
IP20
Output current
Continuous (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (60 s overload) [A]
Continuous kVA (400 V AC) [kVA]
Continuous kVA (480 V AC) [kVA]
Maximum input current
Continuous (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (60 s overload) [A]
Additional specifications
Maximum cable size (mains, motor,
brake) [mm
2
/AWG]
Estimated power loss at rated
maximum load [W]
Weight enclosure IP20 [kg]
8
8
Efficiency [%]
4)
Table 8.3 Mains Supply 3x380–480 V AC - Normal Duty
1) Heavy duty=150–160% current during 60 s, Normal duty=110% current during 60 s.
2) American Wire Gauge.
3) The typical power loss is at nominal load conditions and expected to be within
cable conditions).
Values are based on a typical motor efficiency (IE2/IE3 border line). Motors with lower efficiency add to the power loss in the frequency
converter and motors with high efficiency reduce power loss.
Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses
may rise. LCP and typical control card power consumptions are included. Further options and customer load may add up to 30 W to the
losses. (Though typical only 4 W extra for a fully loaded control card, or field bus, or options for slot B).
For power loss data according to EN 50598-2, refer to www.danfoss.com/vltenergyefficiency
4) Measured using 5 m screened motor cables at rated load and rated frequency for enclosure types J1–J5, and using 33 m screened
motor cables at rated load and rated frequency for enclosure types J6 and J7. For energy efficiency class, see chapter 8.2.1 Ambient
Conditions. For part load losses, see www.danfoss.com/vltenergyefficiency.
46
Quick Guide
Q11K
11
J4
23
21
25.3
15.94
17.5
22.1
18.4
24.3
2)
289.53
3)
9.4
97.8
Danfoss A/S © Rev. 06/2014 All rights reserved.
Q15K
Q18K
Q22K
Q30K
15
18.5
22
J4
J5
J5
31
37
42.5
27
34
40
34.1
40.7
46.8
21.48
25.64
29.45
22.4
28.3
33.3
29.9
35.2
41.5
24.7
29.3
34.6
32.9
38.7
45.7
2
16 mm
393.36
402.83
467.52
9.5
12.3
12.5
97.8
98.1
97.9
1)
Q37K
Q45K
30
37
45
J6
J6
J6
61
73
90
52
65
77
67.1
80.3
99
42.3
50.6
62.4
43.2
54.0
64.0
57
70.3
84.2
49.3
60.8
72.7
62.7
77.3
92.6
2
50 mm
630
848
1175
22.4
22.5
22.6
98.1
98.0
97.7
± 15% (tolerence relates to variety in voltage and
Q55K
Q75K
55
75
J7
J7
106
147
96
124
116.6
161.7
73.4
101.8
79.8
103.1
102.9
140.3
88.8
121.1
113.2
154.3
2
85 mm
1250
1507
37.3
38.7
98.0
98.2
MG06A502