Application Examples - Danfoss VLT AutomationDrive FC 360 Quick Manual

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Application Examples

6 Application Examples
The examples in this section are intended as a quick
reference for common functionalities.
FC
+24 V
12
D IN
18
D IN
19
COM
20
D IN
27
D IN
29
D IN
32
D IN
33
D IN
31
+10 V
50
A IN
53
A IN
54
COM
55
A OUT
42
A OUT
45
Table 6.1 AMA with T27 Connected
FC
+24 V
12
18
D IN
19
D IN
20
COM
27
D IN
29
D IN
32
D IN
33
D IN
D IN
31
+10 V
50
+
A IN
53
A IN
54
COM
55
-
42
A OUT
0 ~10 V
A OUT
45
Table 6.2 Analog Speed Reference (Voltage)
MG06A502
Quick Guide
Parameters
Function
Setting
1-29 Automatic
[1] Enable
Motor
complete
Adaptation
AMA
(AMA)
5-12 Terminal 27
[2]* Coast
Digital Input
inverse
* = Default value
Notes/comments: Parameter
group 1-2* Motor Data must be
set according to motor
NOTICE
If terminal 12 and 27 are
not connected, set 5-12 to
[0]
Parameters
Function
Setting
6-10 Terminal 53
0.07 V*
Low Voltage
6-11 Terminal 53
10 V*
High Voltage
6-14 Terminal 53
Low Ref./Feedb.
0
Value
6-15 Terminal 53
High Ref./Feedb.
1500
Value
6-19 Terminal 53
[1] Voltage
mode
* = Default value
Notes/comments:
Danfoss A/S © Rev. 06/2014 All rights reserved.
FC
+24 V
12
D IN
18
D IN
19
COM
20
D IN
27
D IN
29
32
D IN
33
D IN
D IN
31
+10 V
50
+
A IN
53
A IN
54
COM
55
-
A OUT
42
4 - 20mA
A OUT
45
Table 6.3 Analog Speed Reference (Current)
FC
+24 V
12
D IN
18
D IN
19
COM
20
D IN
27
D IN
29
D IN
32
D IN
33
D IN
31
+10 V
50
A IN
53
A IN
54
COM
55
A OUT
42
A OUT
45
Table 6.4 Start/Stop with Reversing and 4 Preset Speeds
Parameters
Function
Setting
6-12 Terminal 53
4 mA*
Low Current
6-13 Terminal 53
20 mA*
High Current
6-14 Terminal 53
Low Ref./Feedb.
0
Value
6-15 Terminal 53
High Ref./Feedb.
1500
Value
6-19 Terminal 53
[0] current
mode
* = Default value
Notes/comments:
Parameters
Function
Setting
5-10 Terminal 18
[8] Start
Digital Input
5-11 Terminal 19
[10]
Digital Input
Reversing*
5-12 Terminal 27
[0] No
Digital Input
operation
5-14 Terminal 32
[16] Preset
Digital Input
ref bit 0
5-15 Terminal 33
[17] Preset
Digital Input
ref bit 1
3-10 Preset
Reference
Preset ref. 0
25%
Preset ref. 1
50%
Preset ref. 2
75%
Preset ref. 3
100%
* = Default value
Notes/comments:
37
6
6

Advertisement

Table of Contents
loading

Table of Contents