Minolta CA-100Plus Instruction Manual page 14

Crt color analyzer
Table of Contents

Advertisement

Main Body
<Front>
1 POWER switch ........................................ • Used to turn ON and OFF the power to the instrument. (Page 29)
2 Digital display section ............................. • Displays the measured values.
3 Analog display section ............................ • Displays the difference (%) between the measured value and the
4 Measurement mode indications ................. • Displays the measurement mode in which the measured values are
Measurement mode
xyLv mode
T∆uvLv mode
Analyzer mode (G reference)
Analyzer mode (R reference)
u'v'Lv mode
XYZ mode
5 LCD display............................................... • Displays the memory channel, probe no., ID name, warning and
6 HOLD LED ............................................... • Lights up during hold.
7 REMOTE LED .......................................... • Lights up when the instrument is ready for communication with
8 Key panel ................................................. • Used to select/set probe no., SYNC mode, measurement speed,
9 Tilt stand
<Rear>
0 Probe connector [P1] ............................... • Used to connect a measuring probe. (Page 26)
A USB connector ......................................... • USB interface for communication with the PC etc. (Page 86)
B RS-232C connector ................................. • RS-232C compatible interface for communication with the PC etc.
C Vertical synchronizing signal ................... • Input the display's vertical synchronizing signal into this terminal
input terminal
D AC power connector ................................ • Connect the AC power cord to this connector to supply power to
E 4-point expansion board slot ................... • Used to install the optional 4-point expansion board (CA-B04).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
target color or the difference (%) between measured values.
• The range for each dot can be set between 0.1 and 99%. (Page 69)
displayed. (Page 40)
• The table below shows the relationship between measurement
modes and data displayed in the digital display section 2 and ana-
log display section 3.
2 2 2 2 2 Digital display
x, y, Lv
T, ∆uv, Lv
R, B, G
R, B, G
u', v', Lv
XYZ
settings.
the PC via RS-232C or USB interface.
analog display range and ID name, as well as entering values. (Page
17)
(Page 84)
when performing measurement in EXT SYNC mode. (Page 28)
the instrument. (Page 28)
• The rating is AC100-240V, 50-60 Hz, 50VA.
(Page 27)
11
3 3 3 3 3 Analog display
∆x, ∆y, ∆Lv
∆x, ∆y, ∆Lv
R/G, B/G, ∆G
∆R, B/G, G/R
∆x, ∆y, ∆Lv
∆x, ∆y, ∆Lv