1. Installation

Connecting the continuing remote field bus

Continuing
remote field bus
7
6
8
9
1
3
2
Pin selection
9-pin plug with pin insert,
screened/shielded with sleeve/housing.
Possible designs:
a) straight socket
b) angled socket
c) angled socket
(locking)
Cable selection
2
LIYCY 3x2x0.25 mm
IBS RBC METER-T
CP FB6-E 9809c
Pin no. *
Designation
1
DO
2
/DO
3
DI
4
/DI
5
4
5
Earth/GND
9
RBST
Sleeve
Screening
* Do not connect pins not listed here
Part no.
a) RC-09 P 1 N 128 049
b) RC-09 P 1 N 12T 049
c) RC-09 P 3 N 12T 0Z0
28 06 28 6
Meaning
Data out
Data out inverse
Data in
Data in inverse
Reference conductor
Bridge to pin 5
Screening/shielding