2. Commissioning
The following examples show the different address as-
signments and the position of the low byte (n) and the
high byte (n+1). A distinction is made here between the:
– Siemens mode and the
– Standard mode
Example:
– In the Siemens mode the lower value output byte
– In the Standard mode the lower value output byte
In the following chapters you will find instructions on
modifying the position of the low bytes and high bytes
("Byte swap").
– with hardware by means of the DIL switch setting
– with software in a user-friendly manner by re-addres-
2-20
(byte n) is mapped on valve coils 0-7 of the valve
terminal, byte n+1 is mapped on coils (8-15), etc.
(byte n) is mapped on valve coils 8-15 of the valve
terminal, byte n+1 is mapped on coils 0-7.
(chapter 2.4.2, "Manufacturer-specific addressing by
means of the DIL switch")
sing with the CMD software (chapter 2.4.3 "Process
data assignment by means of CMD software"). The
DIL switch setting remains unchanged (factory set-
ting).
CP FB6-E 9809c