A. Technical appendix
Operating voltage
Electronic components and input modules
Pin 1
Operating voltage connection
- rated value
- tolerance
Current consumption
- Pin 1 node FB6-E
- Complete electronics of the CP system
Residual ripple
Power failure bridging time
Operating voltage
Solenoid valves of CP terminal
Pin 2
Operating voltage connection
- rated value
- tolerance
Current consumption
• Pin 2 node FB6-E
Residual ripple
Power failure bridging time
A-4
DC 24 V
20.4 .. 26.4 V
250 mA
see "CP system" manual,
Chapter 3.1.2, Table of current consumption
4 Vpp (within tolerance)
20 ms
DC 24 V
20.4 .. 26.4 V
Sum of all connected
CP solenoid valves;
see "CP pneumatics" manual
4 Vpp (within tolerance)
20 ms
CP FB6-E 9808c