3. Diagnosis
LEDs
Operating status
RC
String assignment modified:
BA
INTERBUS is active; Data
RD
exchange with CP system is
blocked.
String x
RC
INTERBUS not active
BA
RD
By pressing the SAVE button you
can change the address length of
the CP system compared with the
last saved
RC
INTERBUS active;
BA
Data exchange with CP system
RD
blocked, as address length
in the module and string assign-
ment on CP system differ.
CP FB6-E 9809c
(
= lights up;
= LED flashes;
= out)
Error treatment
• Adapt string assignment
or
• press SAVE button to save
new string assignment
• Switch off the operating
voltage and then switch
on again.
When switched on, the CP
system is available for the
field bus module with the new
saved address length.
3-7