1. Installation

Connecting the continuing installation remote bus

Continuing
installation
remote bus
7
6
8
9
1
3
2
Plug selection
9-pin plug with socket insert,
screened/shielded with sleeve/housing.
Possible designs:
a) straight socket
b) angled socket
c) angled socket (locking)
Cable selection
2
LIYCY 3x2x0.25 mm
+ 3 x 1 mm
IBS INBC METER/S (resistant to welding)
CP FB6-E 9809c
Pin no.
Designation
1
DO
2
/DO
3
DI
4
/DI
5
Earth/GND
5
6
FE
4
7
+ 24 V
8
+ 0 V
9
RBST
Sleeve
Screening
Part no.
a) RC-09 P 1 N 128 049
b) RC-09 P 1 N 12T 049
c) RC-09 P 3 N 12T 0Z0
2
28 59 87 0
Meaning
Data out
Data out inverse
Data in
Data in inverse
Reference conductor
Functional earthing of
installation remote bus
Supply to
installation remote bus
Supply to
installation remote bus
Create bridge to
pin 5
Screening/shielding