Enabling Wiegand Front End Mode; Wiegand Keypad Data; Programming The Facility Code For Wiegand Keypad Data; Card Data - IEI Technology prox.pad Installation & Programming Manual

Proximity reader/keypad access control
Table of Contents

Advertisement

prox.pad Installation/Programming Manual
3.3.3

Enabling Wiegand Front End Mode

The prox.pad is defaulted to operate in standalone mode. To use it as a Wiegand Front End you must change the operating mode. First,
change it to Front End Mode, then change it to Weigand Front End Mode. Use the following commands to change the operating mode.
1. Enter Program Mode.
Press: 99 # master code *
The yellow LED blinks slowly.
2. Program the prox.pad for Front End Mode operation.
Press: 30 # 3 # 1 # **
3. Program the prox.pad for Weigand Front End Mode.
Press: 30 # 15 # 0 # **
4. Exit Program Mode.
Press: *
The yellow LED stops blinking.
3.3.4

Wiegand Keypad Data

The prox.pad transmits keypad data as 26-Bit wiegand card data after you press the * key. If you have auto-entry enabled, as soon as
you've entered the final digit in the code, the data is sent. Remember, when auto-entry is used, the code must be the same length as the
master code.
When the prox.pad sends the 26-Bit data, the facility code programmed in command 32, option 2 is used in the data. Please refer to
section 3.3.5 below for details.
Since the keypad only transmits as 26-Bit data, codes can't exceed 65535. This is because there are only 16 bits availible in the 26 bit
data stream. If you enter a code that exceeds this number a single long beep is generate, indicating the value is too large, and the data
is not sent.
It is not possible to perform "Card and Code" operation (requiring both) to gain access in this mode.
3.3.5

Programming the Facility Code for Wiegand Keypad Data

This option is used to set the facility code used when you are using the prox.pad as a keypad front end. This value must match the
facility code used in your panel if required. The default value in prox.pad is 1.
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. Enter the facility code (value = 0 to 255).
Press: 32 # 2 # value # **
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
3.3.6

Card Data

When an HID format card is presented, the raw card data stored on the card is sent directly to the Wiegand panel without any data
manipulation by the prox.pad. You can use any HID format card up to 40 bits. Simply present the card to reader and data is
immediately transmitted.