3.4
Wiegand Programming Commands
If you need to change any of the program default values or wish to add functions, first enter program mode and then enter the desired
program command. Defaults are in bold.
Note: The master code must be changed prior to performing any programming on the prox.pad unit.
Action Desired
Enter Program Mode
Change master code
Set/clear standard option
Option
0 – Audio Keypress Feedback
1 – Visual Keypress Feedback
2 – Auto Entry
3 – Operating Mode
9 – Wiegand Red LED Enable
10 – Wiegand Red LED Active State
11 – Wiegand Geen LED Enable
12 – Wiegand Green LED Active State
15 – Front End Mode Select
Change Platform Parameters
Parameter
0 – Wiegand Pulse Width
1 = Wiegand Interpulse Spacing
2 – 26-Bit Facility Code (for keypad output)
Delete Entire Memory and Reset
System Defaults
To exit Program mode
Document # 6055676, Rev 2.2, D4b
Table 10: Wiegand Programming Commands
Press
99 # (Master Code)*
1 # (new code) * (repeat code) *
Ex: 1 # 4321 * 4321 *
30 # option # s/c # **
Set
1 = Enabled
1 = Enabled
0 = Disabled
0 = Standalone
0 = Disabled
0 = Low
0 = Disabled
0 = Low
0 = Wiegand Front End
32 # parameter # value # **
46 # 00000 # 00000 # **
Press *
prox.pad Installation/Programming Manual
Details
Yellow LED blinks slowly
Code-only operation
See Chart below
Clear
0 = Disabled
0 = Disabled
1 = Enabled
1 = Front End
1 = Enabled
1 = High
1 = Enabled
1 = High
1 = Secured Series Front
End
See Chart Below
Value
1 – 255; 20μS increments;
(Defaults to 8 = 160μS)
1 – 255; 20μS increments;
(Defaults to 32 = 640μS)
0 – 255 (Default = 1)
Yellow stops flashing