prox.pad Installation/Programming Manual
2.9
Standalone Program Commands
If you need to change any of the program default values or wish to add functions, first enter program mode and then enter the desired
program command. Defaults are in bold.
Note: The master code must be changed prior to performing any programming on the prox.pad unit.
Action Desired
Enter Program Mode
Change master code
Set main relay time
Set AUX relay output
Delete Users
Set/clear standard option
Option
0 – Audio Keypress Feedback
1 – Visual Keypress Feedback
2 – Auto Entry
3 – Operating Mode
4 – Facility Code Access
5 – Forced Door Audio Alert
6 – Propped Door Audio Alert
7 – Internal REX Switch
8 – Daylight Savings Time Format
13 – Daylight Savings Time
14 – Prox Card Anti-Passback Select
18 – Invalid PIN Lockout Select
19 – Invalid PIN Lockout Action
Print User List
Print User List
(From Certain User Location)
Page 56 of 86
Table 8: Standalone Programming Commands
Press
99 # (Master Code)*
1 # (new code) * (repeat code) *
Ex: 1 # 4321 * 4321 *
11 # tt # 0 # **
15 # output # 0 # **
user location # **
30 # option # s/c # **
Set
1 = Enabled
1 = Enabled
0 = Disabled
0 = Standalone
0 = Disabled
0 = Disabled
0 = Disabled
0 = Disabled
0 = US
0 = Disabled
0 = Disabled
0 = Disabled
0 = Timed Lockout
25 # 0 # 0 # **
25 # 0 # start user # **
Details
Yellow LED blinks slowly
Code-only operation
tt=1-99 seconds (default = 5
seconds)
0=disabled
1=shunt (default)
2=forced door
3=propped door
(See section 2.7.3)
See Chart below
Clear
0 = Disabled
0 = Disabled
1 = Enabled
1 = Front End
1 = Enabled
1 = Enabled
1 = Enabled
1 = Enabled
1 = European
1 = Enabled
1 = Enabled
1 = Enabled
1 = Forced Door Output
(See section 2.8.2.D)
Document # 6055676, Rev 2.2, D4b