prox.pad Installation/Programming Manual
2.6
Testing the prox.pad
At this point in a typical installation, it is assumed that the prox.pad unit has been mounted and wired successfully as described earlier
and that testing can begin. IEI recommends, however, that first-time installers test the prox.pad unit BEFORE actually mounting and
wiring the unit to become familiar with its operation.
2.6.1
Testing the Controller/Keypad
1. Connect the positive (+) lead of the power supply to the V+ input on the prox.pad controller/keypad.
2. Connect the negative (-) lead of the power supply to the V- input on the prox.pad controller/keypad.
3. Turn ON the power supply.
4. Ensure that the bi-color LED (red and green) on the prox.pad unit lights red.
5. Perform the keypad self-test described in section 5.2.
6. Enter the master code on the keypad by pressing: 99 # Master Code * (default is 1234)
The red LED turns OFF and the green LED turns ON for five seconds while the main relay energizes. To program the unit,
see section 2.7.
Page 34 of 86
Document # 6055676, Rev 2.2, D4b