Enabling/Disabling Auto-Entry; Enabling/Disabling The Internal Request To Exit (Rex) Switch - IEI Technology prox.pad Installation & Programming Manual

Proximity reader/keypad access control
Table of Contents

Advertisement

2.7.5.c

Enabling/Disabling Auto-Entry

Auto-Entry is a feature that determines whether or not you need to press the * key after entering your access code on the keypad. By
default, the feature is disabled which means you are required to enter the * key after your access code to gain entry. If you enable the
feature you are not required to enter the * key after entering your code to gain entry. This feature applies only to codes that are the
same length as the master code. For example if the master code is four-digits, your user code must be four digits to use the auto-entry
feature. All codes less than four digits require the * key. Codes longer than the master code are not allowed, since you'll reach that
number of digits prior to entering the * key.
Note: When auto-entry is enabled you do not have to press the * key after "99 # master code" to enter program mode.
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. To enable this feature, press: 30 # 2 # 1 # **
The yellow LED continues to blink slowly.
To disable this feature, press: 30 # 2 # 0 # **
The yellow LED continues to blink slowly.
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
2.7.5.d

Enabling/Disabling the Internal Request to Exit (REX) Switch

The internal REX switch refers to the button on the circuit board you can use as REX switch using the REX filler piece that comes
with the unit. This feature is disabled by default. Refer to section 1.15.3 and for further details on configuring the internal REX switch.
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. To enable this feature, press: 30 # 7 # 1 # **
The yellow LED continues to blink slowly.
To disable this feature, press: 30 # 7 # 0 # **
The yellow LED continues to blink slowly.
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
Document # 6055676, Rev 2.2, D4b
prox.pad Installation/Programming Manual
Page 47 of 86