1.18

Defaulting prox.pad Memory

If necessary, the prox.pad main memory can be defaulted (erased). This procedure explains how to do this; see Figure 8 below. You
would default the memory, if, for instance, static discharges have corrupted the prox.pad unit, during shipping or installation. You can
also do this if you have simply forgotten the Master Code and you need to enter program mode.
With the power on, remove the case from the prox.pad front controller/keypad to access the main circuit board. (For a visual reference
of the main printed circuit board and the related pin connectors, see
the main printed circuit board, to guard against possible static discharges, touch a grounded object before touching the prox.pad unit.)
1. With the power on, press and hold the Program button (located on the rear side of the main printed circuit board) for two
seconds and release. The yellow LED flashes slowly.
2. Enter the following on the keypad:
46 # 00000 # 00000 # **
The yellow LED flickers rapidly for several seconds and then blinks slowly.
3. Once the memory reset is complete press * to exit program mode then re-assemble the unit.
NOTE: CONNECTING DOOR LOOP INPUT - Before powering up the prox.pad unit, connect the Door Loops input to the "Loop
Common." This prevents "Forced Door" or "Propped Door" conditions from developing upon power-up.
Document # 6055676, Rev 2.2, D4b

Figure 8: Program Button Location on Main Circuit Board

prox.pad Installation/Programming Manual
Figure
2.
Table 2
describes these pins in detail.) (When handling
Page 25 of 86