2.7.5.h

Programming the Facility Code for Card Programming without Presentation

This option is used to set the facility code used when you are programming card users using commands 51 and 56. Prior to
programming users using these commands you must set this value to match that of the cards you are programming. The default value
in prox.pad is 1. IEI HID format proximity cards come with a facility code value of 11.
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. Enter the facility code (value = 0 to 255).
Press: 32 # 2 # value # **
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
2.7.5.i

Programming Invalid PIN Lockout

This feature refers to the number of invalid keypad attempts you can make on the keypad before the keypad either locks out the
keypad or triggers the forced door output. It's used to keep people from continually attempting to gain access to the door by entering
various code combinations by trying to guess a code.
This feature is enabled/disabled through command 30, option 18. It is disabled by default. See below.
As codes are entered, the prox.pad maintains a count of the number of consecutive invalid keypad PINs that are entered. When the
invalid PIN count reaches the value programmed in command 32, parameter 4 (defaulted to 5 attempts), the invalid PIN lockout is
activated.
One of two possible actions occurs once Invalid PIN lockout is triggered. Either a timed lockout occurs or the forced door output is
activated, depending on which action you programmed. The action taken is programmed using command 30, option 19. Activation of
the invalid PIN lockout is noted in the log with an event.
There are a couple of ways to reset this count prior reaching the count limit. You can reset it by either entering a valid keypad code,
presenting a programmed prox card, pressing the program button, entering a valid [99 # Master code*] sequence or by the expiration
of the keypad timer.
Please keep in mind, presenting a valid but non-programmed prox card does not affect (clear or increment) the current invalid PIN
entry count. However, entering an incorrect master code in a [99 # Master Code*] sequence does increment the invalid PIN entry
count. This ensures that attempts to guess the master code are not overlooked.
To enable/disable this feature use the following command sequence:
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. To enable this feature, press: 30 # 14 # 1 # **
The yellow LED continues to blink slowly.
To disable this feature, press: 30 # 14 # 0 # **
The yellow LED continues to blink slowly.
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.