Sign In
Upload
Manuals
Brands
IEI Technology Manuals
Keypad
prox.pad
IEI Technology prox.pad Manuals
Manuals and User Guides for IEI Technology prox.pad. We have
1
IEI Technology prox.pad manual available for free PDF download: Installation & Programming Manual
IEI Technology prox.pad Installation & Programming Manual (86 pages)
Proximity Reader/Keypad Access Control
Brand:
IEI Technology
| Category:
Keypad
| Size: 5.72 MB
Table of Contents
Table of Contents
2
Chapter 1: Introduction/Installation
8
About this Manual
8
Safety Warnings and Cautions
8
Design Change Disclaimer
8
Reproduction Disclaimer
8
FCC Statement
8
Technical Support
9
Warranty
9
Items Supplied from the Factory
10
Items the Installer Must Supply
10
General Description
11
Operating Modes
11
Prox.pad Specifications
12
Table 1: Prox.pad Specifications
12
Installation Configurations
13
Other Installation Considerations
14
Power Supply/Current Requirements
14
Gang Box and Mounting
14
Mounting the Unit on Metal
14
RF Interference
14
Checking the Cables
15
Figure 1: Prox.pad Wiring Harness
15
Figure 2: Identifying Pin Connectors
16
Table 2: Prox.pad Pin Connectors
17
Table 3: IEI-Supplied Parts/Optional Items
18
Mounting the Prox.pad Unit
19
Performing a Wall Mounted Installation
19
Figure 3: Performing a Wall Mounted Installation
19
Performing a Glass Mounted Installation
20
Figure 4: Performing a Glass Mounted Installation
20
Performing a Secure Installation
21
Figure 5: Performing a Secure Installation
22
Installing a Tamper Switch
23
Mounting over a Metal or Plastic Single Gang J-Box
23
Wall Mounting
23
Figure 6: Tamper Switch Locations
23
Removing/Inserting Circuit Boards
24
Figure 7: Removing/Inserting Printed Circuit Board
24
Defaulting Prox.pad Memory
25
Figure 8: Program Button Location on Main Circuit Board
25
Chapter 2: Standalone Mode
26
Standalone Mode Description
26
Standalone Features
26
Inputs/Outputs
26
Unit Capacity
27
Alarm Output Selection
27
Wiring the Prox.pad Unit
28
Wiring the AUX Relay for Use as Alarm Shunt
28
Figure 9: Wiring the Aux Relay for Alarm Shunt Operation
28
Wiring the AUX Relay for Use as Forced Door
29
Figure 10: Wiring the Aux Relay for Forced Door Alarm
29
Wiring the AUX Relay for Use as Propped Door
30
Figure 11: Wiring the Aux Relay for Propped Door Alarm
30
Wiring the Door Contact Input
31
Figure 12: Wiring the Door Contact Input
31
Wiring an External REX Switch (Request to Exit)
32
Figure 13: Wiring the REX Switch
32
Wiring the Main Relay
33
Figure 14: Electric Strike (Fail Secure) Wiring
33
Figure 15: Maglock (Fail Safe) Wiring Diagram
33
Testing the Prox.pad
34
Testing the Controller/Keypad
34
Programming in Standalone Mode
35
General Programming Features
35
Changing the Master Code
35
B Prox.pad Default Settings
36
Table 4: Prox.pad Default Settings - Standalone Mode
36
C Prox.pad LED Indicators/Sounder Operations - Standalone Mode
37
Table 5: Prox.pad LED Indicators/Sounder Operations - Standalone Mode
37
Programming Users
38
User Types
38
Programming a "Code Only" User
38
Table 6: Prox.pad User Types
38
Programming "Card Only" Users by Presentation
39
Programming 26-Bit "Card Only" Users Without Presentation
39
Programming "Code and Card" Users
39
Programming "Code or Card" Users
40
Programming 26-Bit "Card Only" Users Via Batch Entry Without Presentation
40
Programming Consecutive "Card Only" Users Via Batch Entry by Presentation
41
Command 50 Quick Program Feature - "Code Only" or "Card Only
41
Deleting Users
42
Deleting a Single User
42
Deleting a Block of Users
42
Programming Output Relays and Audio Alerts
43
Changing the Main Relay Time
43
Programming the Aux Relay Output Function
43
Programming the Propped Door Audio Alert
44
Programming the Forced Door Audio Alert
44
Programming the Propped Door Time
45
Programming the Forced Door Time
45
Programming Keypad Options and Parameters
46
Enabling/Disabling Audio Keypress Feedback
46
Enabling/Disabling Visual Keypress Feedback
46
Enabling/Disabling Auto-Entry
47
Enabling/Disabling the Internal Request to Exit (REX) Switch
47
Enabling/Disabling Daylight Savings Time
48
Selecting Daylight Savings Time Format
48
Programming Timed Anti-Passback
49
Programming the Facility Code for Card Programming Without Presentation
50
Programming Invalid PIN Lockout
50
Reseting System Defaults and Erasing Memory
52
Erasing Entire Memory/Resetting System Defaults
52
Using the Printing Features
53
Selecting Transaction Log Information
53
Table 7: Transaction Log Events
53
Dumping a Transaction Event Log
54
Programming a Log Dump Code or Card
54
Dumping a Transaction Log Manually
54
Erasing the Transaction Log Memory
55
Dumping a Programmed User List
55
Standalone Program Commands
56
Table 8: Standalone Programming Commands
56
Chapter 3: Wiegand Front End Mode
60
Wiegand Front End Mode Description
60
Wiring the Wiegand Front End
60
Figure 16: Wiring to a Wiegand Panel
60
Wiegand Front End Programming
61
Entering Program Mode
61
Changing the Master Code
61
Enabling Wiegand Front End Mode
62
Wiegand Keypad Data
62
Programming the Facility Code for Wiegand Keypad Data
62
Card Data
62
Enabling/Disabling Audio Keypress Feedback
63
Enabling/Disabling Visual Keypress Feedback
63
Enabling/Disabling Auto-Entry
64
Enabling/Disabling the Red LED
64
Enabling/Disabling the Green LED
65
Programming the Red LED Active State
65
Programming the Green LED Active State
66
Programming the Wiegand Pulse Width
66
Programming the Wiegand Inter-Pulse Spacing
67
Reseting System Defaults and Erasing Memory
67
Wiegand Mode LED Indicators/Sounder Operations
68
Wiegand Front End Mode Default Settings
68
Table 9: Prox.pad LED Indicators/Sounder - Wiegand Mode
68
Wiegand Programming Commands
69
Table 10: Wiegand Programming Commands
69
Chapter 4: Secured Series Front End Mode
70
Secured Series Front End Mode Description
70
Wiring the Secured Series Front End
70
Figure 17: Wiring the Prox.pad to the Secured Series DCM
70
Secured Series Front End LED Indicators/Sounder Operations
71
Secured Series Front End Mode Default Settings
71
Table 11: Prox.pad LED Indicators/Sounder Operations - Secured Series Mode
71
Secured Series Front End Programming
72
Entering Program Mode
72
Changing the Master Code
72
Enabling Secured Series Front End Mode
73
Selecting the Card Type
73
In/Out Select
74
Enabling/Disabling Facility Code Matching
74
Programming Facility Code
75
Corporate 1000 Company ID
75
Programming Timed Anti-Passback
76
Enabling/Disabling Audio Keypress Feedback
77
Enabling/Disabling Visual Keypress Feedback
77
Enabling/Disabling Auto-Entry
78
Reseting System Defaults and Erasing Memory
78
Secured Series Front End Program Commands
79
Table 12: Secured Series Front End Programming Commands
79
Chapter 5: Troubleshooting
80
Before Calling IEI
80
Performing a Keypad Self-Test
80
Table 13: Troubleshooting Chart
81
Troubleshooting Flow Charts
82
Performing Power Supply Integrity Test
85
Correcting Possible Water Problems
85
Silicone
85
Advertisement
Advertisement
Related Products
IEI Technology prox.pad Plus
IEI Technology PM-PV-D4251
IEI Technology PPC-5xxx-9455
IEI Technology PPC-F15B-BTi
IEI Technology PCISA-MARK
IEI Technology PPC-3712A/B-N270
IEI Technology PPC-F08B-BT
IEI Technology PCISA-6612
IEI Technology PPC-F15D-ULT5-i5/4G/PC
IEI Technology PICOe-6612 Series
IEI Technology Categories
Motherboard
Touch Panel
Computer Hardware
Single board computers
Desktop
More IEI Technology Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL