3.3.15

Programming the Wiegand Inter-Pulse Spacing

If you panel requires a specific inter-pulse spacing (the width between each data bit) you can program that with the parameter below.
It's programmable from 20μS (micro-seconds) to 5100μS; the default value is 640μS. The value field in the command
requires a number from 1 to 255 in 20μS increments. For example is you want 200μS enter a value of 10 in the field. Only
change this option if your panel specifically states you need a specific inter-pulse spacing.
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. Enter the pulse width (value = 1 to 255; 20μS increments; default = 32, 640μS).
Press: 32 # 1 # value # **
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
3.3.16

Reseting System Defaults and Erasing Memory

Entering command 46 deletes everything from the prox.pad memory except the transaction log and restores the default settings.
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. Enter the command to erase memory.
Press: 46 # 00000 # 00000 # **
The yellow LED blinks rapidly for several seconds until the memory is deleted.
3. Exit Program Mode.
Press: *
Document # 6055676, Rev 2.2, D4b
prox.pad Installation/Programming Manual
Page 67 of 86