Action Desired
Change Platform Parameters
Parameter
2 – 26 Bit Facility Code (for commands 51 &
56)
3 – Process Card Timer
4 – Invalid PIN Lockout Attempts
5 – Invalid PIN Lockout Duration
Set System Time
Set System Date
Set Door Number
Set Propped Door Time
Set Forced Door Time
Reset System Defaults Only
Delete Entire Memory and Reset
System Defaults
Program User – Code Only
Program User – Code AND Card
By Presenting Card
Document # 6055676, Rev 2.2, D4b
Press
32 # parameter # value # **
Value
0 – 255; (Default = 1)
Note: IEI Cards are Facility Code 11
2 – 240; ¼ sec. Increments
(Defaults to 4 = 1 sec.)
1 – 50 (Default = 5)
1 – 255; 5 sec. increments;
(Defaults to 60 = 5 Minutes)
41 # hhmm # 0 # **
42 # mmddyy # dow # **
43 # nnnn # 0 # **
44 # ttt # 0 # **
45 # ttt # 0 # **
40 # 00000 # 00000 # **
46 # 00000 # 00000 # **
50 # user type # user location #
code *repeat code *
50 # user type # user location #
code * repeat code * <present
card>
prox.pad Installation/Programming Manual
Details
See Chart Below
hhmm=hour/minute (24 Hour
Format)
mmddyy=month, date, year;
dow=day of week, 1=Sunday
nnnn=door number (4 digits)
ttt=propped door time, to nearest
10's seconds, entered as 30-990;
(default=30 secs)
(this sets the time for both Aux
Relay and local sounder)
ttt=forced door time, to nearest 10's
seconds, entered as 30-990;
(default=10 secs)
(this sets time for both Aux Relay
and local sounder)
Does not delete users
See section 2.7.6a
Deletes all memory including users
See section 2.7.6b
User Types:
0-Toggle/latch lock
1-Normal access
2-log Dump
3-Lockout
User Types:
0-Toggle/latch lock
1-Normal access
2-log Dump
3-Lockout
Page 57 of 86