2.7.4.e

Programming the Propped Door Time

To program the Propped Door output time use command 44. This time applies to both the audio alert and to the Aux relay, when this
feature is assigned to it. You can program it from 10 to 990 seconds in 10 second increments. The default value is 30 seconds, which
means the output triggers if the door position switch is held open for 30 seconds. The command sequence is as follows:
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. Enter the propped door time (ttt = 10 to 990 seconds).
Press: 44 # ttt # 0 # **
For example, to enter 60 seconds, press: 44 # 60 # 0 # **
The yellow LED continues to blink slowly.
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
2.7.4.f

Programming the Forced Door Time

To program the Forced Door output time use command 45. This time applies to both the audio alert and to the Aux relay, when this
feature is assigned to it. You can program it from 10 to 990 seconds in 10 second increments. The default value is 10 seconds, which
means the output triggers immediately after 10 seconds. The command sequence is as follows:
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. Enter the forced door time (ttt = 10 to 990 seconds).
Press: 45 # ttt # 0 # **
For example, to enter 60 seconds, press: 45 # 60 # 0 # **
The yellow LED continues to blink slowly.
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.