Programming Consecutive "Card Only" Users Via Batch Entry By Presentation; Command 50 Quick Program Feature - "Code Only" Or "Card Only - IEI Technology prox.pad Installation & Programming Manual

Proximity reader/keypad access control
Table of Contents

Advertisement

2.7.2.h

Programming Consecutive "Card Only" Users via Batch Entry by Presentation

To program consecutive "Card Only" user via batch entry by presentation (by presenting cards to the reader) use command 53. This
command provides a simple method of programming a group of consecutive users by presenting the appropriate prox cards. This
method of programming cards does not require any knowledge of the card format as long as it contains 40 bits or less of data. Up to
1,999 users can be added this way at one time. Entering the master user as the first card in the sequence generates an error because the
master code cannot be programmed as a "Card Only" user. The card loading stops automatically once the current user location
exceeds 2000. Pressing any key on the faceplate aborts the loading process.
To add several users from the proximity reader, follow this procedure:
1. Enter Program Mode.
Press: 99 # Master Code *
The yellow LED flashes slowly.
2. Enter command to batch program users.
Press: 53 # user type # start location # * * present cards one after another
NOTE: Never enter one (1) as the starting user location since it is reserved for the master code.
3. Exit program mode.
Press: *
2.7.2.i

Command 50 Quick Program Feature - "Code Only" or "Card Only"

The prox.pad contains a quick method for programming normal access user type users that are usually programmed using command
50. When using this method the 50 is not required in the command sequence.
1. Enter Program Mode.
Press: 99 # master code *
The yellow LED flashes slowly.
2. Program the "Code Only" User.
Press: user location # code * repeat code *
Program the "Card Only" User.
Press: user location # ** <present card>
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
Document # 6055676, Rev 2.2, D4b
prox.pad Installation/Programming Manual
Page 41 of 86

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents