Alarms And Anomalies Display - DITEC Entrematic HomeLink E2H Installation Manual

Control panel for 2-motor 24v automations with built-in radio
Table of Contents

Advertisement

10.3 Alarms and anomalies display

i
WARNING: alarms and anomalies are displayed when any display selection is made. The signaling of
Type of
Display
alarm
M0 - Automation type not selected.
MB - Absence of motor 1 during an ope-
ration.
MC - Absence of motor 2 during an opera-
tion (if 2-motor functioning has been set).
MD - Irregular functioning of motor 1 ope-
ning limit switch.
ME - Irregular functioning of motor 1 clo-
sing limit switch.
MF - Irregular functioning of motor 2 ope-
ning limit switch.
MG - Irregular functioning of motor 2 clo-
sing limit switch.
MH - Incorrect wings overlap.
MI - Detection of third consecutive obsta-
cle.
R0 - Insertion of a memory module contai-
ning more than 100 memorized transmit-
ters.
Warning: the
automatic.
R3 - Memory module not detected.
R4 - Memory module not compatible with
control panel.
Description
setting is
29
Remedy
If the dedicated memory module is present
press
.
Select a type of automation.
ning limit switch.
sing limit switch.
ning limit switch.
sing limit switch.
stacles along the automation path.
mory module, cancel a few memorized
transmitters to bring the total lower than
100.
Set
.
Insert a memory module.
Insert a compatible memory module.
-
-
-
-
-
-