C.16 Calibration Registers — BASE+18 and BASE+19
The MIC-3716 offers Calibration registers BASE+16 and BASE+17
for calibrating A/D and D/A.

Table C-17: Calibration Command and Data Register

Write
Bit #
BASE + 19
BASE + 18
D7 to D0
CM3 to CM0 Calibration Command and Table C-18 lists the
96
Calibration Command and Data
7
6
D7
D6
D5
Calibration data
D0 LSB of the calibration data
D7 MSB of the calibration data
command code for MIC-3716.
5
4
3
CM3
D4
D3
2
1
CM2
CM1
CM0
D2
D1
D0