ABB CL Series Applications Manual page 100

Logic relays
Hide thumbs Also See for CL Series:
Table of Contents

Advertisement

1SVC 440 795 M0100
C1 N
S
0010
â C:0010
I5-------CC1
I6-------RC1
C1=======TT1
T1=======ÄQ1
T1 Ü
S1
00.500
S2
00.250
â T:00.200
If the actual value is greater than or equal to the setpoint
+
(10), the left character on the bottom row will change to
The contact of counter
The counter contact triggers the timing relay. This causes the
warning light to flash at output Q1.
Power flow of the circuit diagram
Doubling the flashing frequency:
S
+
In the power flow display select
X
Press OK.
X
Change the set time
X
(0.5 and 0.25 s).
The set time will be accepted as soon as you press OK.
X
The character on the left of the bottom row will indicate
whether the contact has switched or not.
#
Contact has not switched (n/o contact open).
â
Contact has switched (n/o contact closed).
You can also modify parameter settings via the PARAMETER
menu option.
h
If you want to prevent other people from modifying the
parameters, change the access enable symbol from + to –
when creating the circuit diagram and setting parameters.
You can then protect the circuit diagram with a password.
Function relays
C1
switches.
T1
.
I1
00.500
I2
to
and
â
.
00.250
to
97