Festo CPX Series Electronic Manual page 153

Hide thumbs Also See for CPX Series:
Table of Contents

Advertisement

B. Parameters and data of the CPX terminal
Diagnostic memory parameters: Fault numbers filter
Function no.
3484
Description
With this diagnostic memory filter you can:
– Suppress the recording of a desired error message
– Record exclusively a desired error message
Bit
Bits 4, 5
Values
FN = Fault number
Bit 5
0
0
1
1
Remark
The Fault numbers are determined by means of the diagnostic memory parameter
"Fault number" (function no. 3487).
Table B/27: Fault numbers filter
Diagnostic memory parameters: Module/channel filter
Function no.
3484
Description
The recording of faults of other modules or channels can be suppressed with
this diagnostic memory filter for the analysis of faults of a particular module or
channel.
Bit
Bits 6, 7
Values
FN = Fault number
Bit 7
0
0
1
1
Remark
The numbers are determined by means of the diagnostic memory parameters
"Module and Channel numbers" (function nos. 3485...3486).
Table B/28: Module/channel filter
Festo P.BE-CPX-SYS-EN en 0112NH
Bit 4
Description
0:
Fault numbers filter inactive (pre-setting)
1:
Record only defined FN
0:
Do not record defined FN
1:
Reserved
Bit 6
Description
0:
Module/channel filter inactive (pre-setting)
1:
Record only the FN of a module
0:
Record only the FN of a channel
1:
Reserved