B. Parameters and data of the CPX terminal
Diagnostic memory parameters: Run/Stop filter 2
Function no.
3484
Description
Diagnostic memory filter with which you can determine when the recording of
faults is to be started or stopped.
Bit
Bits 0...2
Values
MN = Module number, CN = Channel number, FN = Fault number
Bit 2
0
0
0
0
1
1
1
1
Remark
The numbers are determined by means of the diagnostic memory parameters
"Module, Channel and Fault numbers" (function nos. 3485...3487).
Table B/25: Run/Stop filter 2
Diagnostic memory parameters: Fault end filter
Function no.
3484
Description
Diagnostic memory filter with which you can determine whether outgoing faults
are to be registered or not.
Bit
Bit 3
Values
0 = Record outgoing faults (end of fault) (filter inactive, pre-setting)
1 = Do not record outgoing faults (end of fault) (filter active)
Remark
By recording the outgoing fault, you can ascertain how long the fault has
existed. Incoming and outgoing faults each represent one entry. With outgoing
faults the Fault number "0" is entered. Maximum 40 entries are saved together.
Table B/26: Fault end filter
B-22
1
0: Description
0
0: Run/Stop filter 2 inactive
0
1: Record up to the defined FN
1
0: Record up to the defined FN + MN
1
1: Record up to the defined FN + MN + CN
0
0: Record as of the defined FN
0
1: Record as of the defined FN + MN
1
0: Record as of the defined FN + MN + CN
1
1: Reserved
Festo P.BE-CPX-SYS-EN en 0112NH