5. Diagnosis and error treatment
15
14
1
1
0
2
Control bit
1
Bit number of the outputs
Fig. 5/7: Reading out function no. 1937
15
14
1
1
2
Quitting bit
1
Bit number of the inputs
Fig. 5/8: Reply data (example)
Festo P.BE-CPX-SYS-EN en 0112NH
Example 1: Check to see if there are diagnostic data
Function no. 1937 specifies whether there are diagnostic data
and contains, where applicable, the number of the first mod-
ule on which a fault has occurred (see section B.2.6.).
Function no. = 1937
1937 dec. = 11110010001 Bin
13
12
11
10
9
8
0
0
0
1
1
1
Function no.
2
Signal status of the outputs
There are diagnostic data if bit 6 supplies a 1-signal. Bits 0...5
contain the module number of the first faulty module (see
also section B.2.6.). If, for example, there were a fault on
module 5 (5 dec. = 101 Bin), the following input data would
be available:
13
12
11
10
9
8
Reserved
2
Signal status of the inputs
7
6
5
4
3
2
1
0
0
1
0
0
7
6
5
4
3
2
0
0
0
0
0
1
Diagnostic data
1
0
0
1
1
0
0
1
5-21