Reporting
Event Description
System-based AUX1 switch trouble
System-based AUX1 switch trouble
restore
System-based AUX2 switch alarm
System-based AUX2 switch alarm
restore
System-based AUX2 switch trouble
System-based AUX2 switch trouble
restore
Voice Aux ECS 1 Alarm
Voice Aux ECS 1 Alarm Restore
Voice Aux ECS 2 Alarm
Voice Aux ECS 2 Alarm Restore
Voice Aux ECS 3 Alarm
Voice Aux ECS 3 Alarm Restore
Voice Aux ECS 4 Alarm
Voice Aux ECS 4 Alarm Restore
Water flow switch alarm
Water flow switch alarm Restore
Water flow switch trouble
Water flow switch trouble Restore
Zone-based AUX1 switch alarm
Zone-based AUX1 switch alarm re-
store
Zone-based AUX1 switch trouble
Zone-based AUX1 switch trouble re-
store
Zone-based AUX2 switch alarm
Zone-based AUX2 switch alarm re-
store
Zone-based AUX2 switch trouble
Zone-based AUX2 switch trouble re-
store
Table 11.2 Point Events
An unexpected SLC device has
been detected
An unexpected SLC device has
been removed
Auxiliary power disabled
Auxiliary power enabled
Auxiliary power Trouble
Auxiliary power trouble restore
132
SIA Reporting Format
SIA pi Modifier
Module
SIA
Parameter Fixed Length
ID # (If
Event
Any)
Codes
UT
1000
UJ
1000
UA
2000
UH
2000
UT
2000
UJ
2000
UA
3
UH
3
UA
4
UH
4
UA
5
UH
5
UA
6
UH
6
SA
Zone #
SH
Zone #
ST
Zone #
SJ
Zone #
UA
Zone # +
1000
UH
Zone # +
1000
UT
Zone # +
1000
UJ
Zone # +
1000
UA
Zone # +
2000
UH
Zone # +
2000
UT
Zone # +
2000
UJ
Zone # +
2000
Note: Point events are reported only when "Report by Point" is selected. When SK protocol
devices are used sensors 1–99 are reported as Pnt #s 1–99, and modules 1–99 are reported as
Pnt #s 201-–299.
pi Exp. ID XE
Point #
pi Exp. ID XI
Point #
pi Exp. ID FB
Point #
pi Exp. ID FU
Point #
pi Exp. ID FT
Point #
pi Exp. ID FJ
Point #
Table 11.3 : Reporting Formats Table
Contact ID Reporting Format
SIA
Qualifier
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
UTNN001000
1
UJNN001000
3
UANN002000
1
UHNN002000
3
UTNN002000
1
UJNN002000
3
UANN003000
1
UHNN003000
3
UANN004000
1
UHNN004000
3
UANN005000
1
UHNN005000
3
UANN006000
1
UHNN006000
3
SANN000ZZZ
1
SHNN000ZZZ
3
STNN000ZZZ
1
SJNN000ZZZ
3
UANN001ZZZ
1
UHNN001ZZZ
3
UTNN001ZZZ
1
UJNN001ZZZ
3
UANN002ZZZ
1
UHNN002ZZZ
3
UTNN002ZZZ
1
UJNN002ZZZ
3
XENNXXPPPP
1
XINNXXPPPP
3
FBNNXXPPPP
1
FUNNXXPPPP
3
FTNNXXPPPP
1
FJNNXXPPPP
3
6808 Manual — P/N LS10146-001SK-E:C 09/28/2017
Event
Group #
Contact #
Code
373
01
000
373
01
000
140
02
000
140
02
000
373
02
000
373
02
000
171
00
000
171
00
000
172
00
000
172
00
000
173
00
000
173
00
000
174
00
000
174
00
000
113
00
Zone #
113
00
Zone #
373
00
Zone #
373
00
Zone #
140
01
Zone #
140
01
Zone #
373
01
Zone #
373
01
Zone #
140
02
Zone #
140
02
Zone #
373
02
Zone #
373
02
Zone #
380
Exp. ID
Point #
380
Exp. ID
Point #
571
Exp. ID
Point #
571
Exp. ID
Point #
320
Exp. ID
Point #
320
Exp. ID
Point #