Art. 4533
IP speaker unit module
ENABLE BOOTLOADER MODE
In case of firmware update failure (i.e. because of mains failure or
cable disconnection during the update etc.) and the door panel is
not anymore recognized by the Videx IP Wizard software, you can
try to restore it by manually putting it into boot mode.
It is strongly recommended that this operation is carried out by
a qualified engineer and in any case after a contact with videx
support.
• Disconnect the door panel from the power supply.
• Press and keep pressed the "J" button (Fig. 2 on page 5) then
connect again the power supply source.
• The door panel goes in boot mode recognized by the four
LEDs flashing alternatively (Fig. 11).
• Now proceed using the utility "VidexFirmwareUpdater.exe" to
upload the firmware to the device.
• If the update process terminates correctly, the device should
be restored and ready to work.
• If the device still not work, please contact the supplier to proceed according to the warranty terms.
TECHNICAL SPECIFICATION
SIGNALS ON SYSTEM CONNECTION TERMINALS
Active low output enabled when the
SL
external video input is in use
EXT
CAMERA
GND Composite video signal ground reference
V
Composite video signal input
A
RS-485 Connection (termination adjusted
RS485
B
through the JP1 jumper)
GND
+12V
POWER
12Vdc 400mA power supply input
GND
Active low input 1 (when enabled activate
PTE1
the relay 1)
INPUTS
Active low input 2 (when enabled activate
PTE2
the relay 1)
GNDP Ground reference to be used with PTE inputs
RX–
Ethernet Connection Orange (568A)
RX+
Ethernet Connection White/Orange (568A)
ETHERNET
TX–
Ethernet Connection Green (568A)
TX+
Ethernet Connection White/Green (568A)
C2
Relay 2 common contact
RELAY 2
NC2
Relay 2 normally closed contact
NO2 Relay 2 normally open contact
C1
Relay 1 common contact
NC1
RELAY 1
Relay 1 normally closed contact
NO1 Relay 1 normally open contact
IPVK/6296 Series - Installation handbook
Door panel in BOOTLOADER mode
Fig. 11
UNIT SPECIFICATION
Housing/Mounting:
Push Buttons:
Programming:
Controls:
Front plate finishes:
Power Supply:
Power consumption:
Working Temperature: -10 +50 °C
Max
12-24
Vac/dc
0.4A
- 8 -
One 4000 Series Module / 4000 Series
Modular System
Yes, from 0 to 2 call buttons depend-
ing on the model
Yes, carried out by the 8 way dip-switch
located on the rear of the module
Microphone and Loudspeaker volume
trimmers
Mirror stainless steel (standard),
Anodized Aluminium (add /a after the
product code) or High Brass (add /HB)
12Vdc - 400mA
Stand-by:
??
mA
Operating:
??
mA
66550062-EN - V 1.1 - 31/05/18