528050-1
Use the Pneum. Parallel Crimp Machine AT-SC only with conditioned air (lubricated and filtered).
Standard Filter: 30 µm
Connect AIR MAX. (Fig. 8.01, Pos. 1) of the Pneum. Parallel Crimp Machine AT-SC to the main air
supply with the included black air hose Ø 8/6 mm.
Working Air Pressure: 6 bar/90psi.
CAUTION!
 Connect compressed air supply with supplied compressed air tube (length 1m).
 The machine can only be depressurized by disconnecting the machine from the
main air supply (Fig. 8.01, Pos 1).
INFORMATION:
Use only lubricated and filtered compressed air.
8.2

Machine Set-Up Adjustments of the TE Crimp System

All Pneum. Parallel Crimp Machines AT-SC are
factory adjusted to the TE Crimp System (SDE
Adapter).
INFORMATION:
Do not change any factory adjusted settings!!
8.2.1

Inspection of the Crimp Height

DANGER!
Due to the risk of hand or finger injury, never try to reach into the machine.
Page 48 / 101
412-18876 Rev. G
ECOC: EGC0 ; LOC: AI