6.
GPIB/RS232 Interface (IEEE-488.2)
6.1 Introduction
The tester can be controlled remotely by PC for data transmission through RS232 or GPIB
(IEEE 488-1978) interface.
6.2
GPIB Interface
6.2.1 Applied Standard
The tester applies the IEEE488-1978 standard.
6.2.2 Interface Capability
Code
SH1
Source Handshake
AH1
Acceptor Handshake
T4
Basic Talker requirement
L4
Basic Listener requirement
SR1
Service request requirement
RL1
All remote/local requirement
PP0
No Parallel poll requirement
DC1
All device clear requirement
DT0
No Device trigger requirement
C0
No controller requirement
6.2.3 Interface Message
The table below lists the Tester's reaction to the following interface messages:
Interface
Meaning
Message
GTL
Go To Local
SDC
Selected Device Clear It clears the selected device.
LLO
Local Lockout
IFC
Interface Clear
Meaning
It switches the Tester to Local mode.
It is prohibited to use ENTER to switch to Local mode.
It clears the GPIB interface.
GPIB/RS232 Interface (IEEE-488.2)
Reaction
6-1