13 – Install (or Replace) Batteries
IMPORTANT: Do not install batteries if controller is
powered by external power supply
To install the batteries, first remove the battery cover
using the security tool provided (Fig. 13A).
4. Unscrew the bottom screw of the battery keeper
and remove the battery keeper, being careful not to
break the tabs at top holding it in place (Fig. 13B) .
5. Place (6) "AA" batteries in the compartment,
being careful to align polarity properly (Fig. 13C).
6. Replace battery keeper being careful to engage
tabs at top to hold it in place (Fig. 13B).
7. Attach battery cover to inside escutcheon
making sure to line up tabs with retaining
slots in battery cover. Secure with the
security screw and tool (Fig. 13A and 13D).
8. Three-pin connector from chassis connects to rail.
4
2
Fig. 13B
14 – Install Rail Assembly
Attach rail assembly according to Exit Installation Instructions A6770.