CP-Parameter
CP.31 Relay output 1 / Function (X2A.24...26)
CP.32 Relay output 2 / Function (X2A.27...29)
The switching level of CP.31 is 100,00. The switching level of CP.32 is CP.33!
Value Function
0
No function (generelly off)
1
Generelly on
2
Run signal; also by DC-braking
3
Ready signal (no error)
4
Fault relay
5
Fault relay (no auto-reset)
6
Warning or error message at abnormal stopping
7
Overload alert signal
8
Overtemperature alert signal power modules
9
External Overtemperature alert signal motor
11
Overtemperature alert signal interior OHI
12
Cable breakage 4...20 mA on analog input 1
14
Max. constant current (stall, CP.25) exceeded
15
Max. ramp current (LA-Stop CP.24) exceeded
16
DC-braking active
20
Actual value=set value (CP.3=Fcon, rcon; not at noP, LS error,SSF)
21
Accelerate (CP.3 = FAcc, rAcc, LAS)
22
Decelerate (CP.3 = FdEc, rdEc, LdS)
23
Real direction of rotation = set direction of rotation
24
Utilization (CP.6) > 100%
25
Active current > switching level
26
Intermediate circuit voltage (CP.7)>switching level
27
Real value (CP.1) > switching level
28
Set value (CP.2) > switching level
31
Absolut set value on AN1 > switching level
32
Absolut set value on AN2 > switching level
34
Set value on AN1 > switching level
35
Set value on AN2 > switching level
40
Hardware current limit activated
41
Modulation on
44
Inverter status (CP.3) = switching level
45
Power module temperatur > Level
46
Motor temperatur > Level
47
Ramp output frequency > Level
48
Apparent current (CP.4) > Level
49
Clockwise rotation (not at noP, LS, abnormal stopping, Fehler)
50
Counter clockwise (not at noP, LS, abnormal stopping, Fehler)
63
Absolut ANOUT1 > switching level
64
Absolut ANOUT2 > switching level
65
ANOUT1 > switching level
66
ANOUT2 > switching level
70
Driver voltage active (safety-relay)
73
Absolute active power > switching level
74
Active power > switching level
Unlisted values are only for application-mode.