Installation

Installation
When unpacking pump, check for shipping damage.
Report any shipping damage to delivering carrier imme-
diately.
CAUTION
Do not use a curb pump automatic shut-off nozzle
with this pump. Use of a curb pump automatic nozzle
may cause priming problems, reduced output flow,
and motor overheating. If an automatic shut-off nozzle
is required, use Graco part number 260082 (regular)
or 260083 (unleaded) or Catlow, Inc. part number
NCLF-1 (regular) or NCNLF-1 (unleaded).

Mounting Pump

CAUTION
Ensure tank being used is clean and free of welding
slag.
Ensure the tank has a vent to allow air into the tank
as the herbicide is being pumped out. Failure to
vent tank will cause priming problems.
1. Apply herbicide compatible sealant to large thread
on bung adapter (9) (2 in. x 1-1/2 in. reducer fitting).
Install bung adapter on tank.
2. Assemble suction tube sections by applying PVC
cement (supplied with your pump) to the inside
diameter of the PVC couplers. Make sure PVC
cement is applied to the complete inside diameter
and slide the pipe sections into the coupler with a
twisting motion.
For tanks deeper than 36 in. (914 mm) you will
need a standard 1 in. (25 mm) pipe with 1 in. npt
threads on one end. Suction tubes longer than 60
in. (1.52 m) require a foot valve (Graco Part No.
260217) at the bottom of the tube to prevent loss of
prime.
3. Cut the suction tube so that it is 2 in. (55 mm) from
the bottom of the tank when installed in the tank.
4. Insert inlet gasket (7) into union nut (1k). Apply a
herbicide compatible sealant to the threads on the
4
suction tube assembly (5c) and screw the suction
tube into the pump inlet (1j).
5. Insert suction tube attached to pump through bung
adapter (9) into tank. Position pump as desired and
tighten union nut (1k) on bung adapter (9).

Mounting Hose and Nozzle

1. Apply herbicide compatible sealant to male threads
on the street elbow fitting (1e) and screw fitting into
the 3/4 in. npt outlet port on the top of pump. Do not
over tighten.
2. Apply herbicide compatible sealant to threads on
both ends of the hose assembly. Screw one end of
hose into the female thread on the fitting (1e) and
tighten.
3. Screw nozzle onto the other end of hose and
tighten.
Electrical Installation
12 VDC
To install wiring for a negative ground system:
1. Ensure pump switch is OFF.
2. To remove electrical cover (2a), remove four bolts
(2c).
Power cable can be cut to shorter length if 18 feet
(5.5 m) is not required. Cut to proper length and
proceed with steps 3 and 4.
3. Strip 3 in. (76 mm) of outside insulation from power
cable (6c) from end opposite of fuse.
4. Strip 3/8 in. (10 mm) of insulation from red and black
wires.
5. Slide strain relief (6b) over end of power cable (6c)
on the end just stripped. Male thread of strain relief
should be toward stripped end.
6. Insert power cable through conduit thread in electri-
cal cover (2a). Connect wires from power cable to
wires from the motor using wire nuts (2e): red to red
and black to black.