Karl Storz Endomat Select UP210 Instruction Manual page 62

Table of Contents

Advertisement

ST0lll
KARL STORZ-ENDOSKOPE
l:::s
t...:>
~
~
~
o
,...,
- , "'C
:, : :
-
·=
-I
~ - ,
-.
:z::
--
-0
C>
=
S=
l>
CZ,
::::,
0
31:
.
·"-,i;;
·;.,''t.,
~ ,
.
tF
.
r,
.,
·1
.
.
~'f-
.,., _·,
=
•k4~~
~r,,
. . . .
. , ; . , -
""; ; : -
·~,
. ,..·9 ·.
n.,J)<;,.
,_...---
-
·-•. : : : -
,
~*
"v'
{j~'/
:w;\
--~
~
.
,
.,J.}.';.
•,~1, i ·
x"t'
·
·"
''"°'
!
.
:.~
'ii•
'
w
.
~
I
""'•
,.,.
'
~
c::
ft; .-v._,~
- =--.,, . ; , o
-
,
~ i1-
,\,,.
~~
r::riy,
,,-.,
.i,
I
e' ~ ,_.
I
.
';:,\
·;;
H
tsS: ~-
-o,. ~
r-\J1
;.
t:
l
.,_
\
j(U'.3,•
\~ .,E1_.,,.,,/i·'· ,,
,
~g~--1--g{
. . .
~-~_.
A
1l~
~~
_,
,::-
~
"'"'~
-,w-
oY~
.
J!,.,f)
'I\'
· ·" ~,
T
L "1'--.;;i
f.
,,
't.\.t'& ~~'
---!....5/
i
~
.1-/'
. . .
:
r7
"~"; ~ >
'p
-
r•.IP'
,
#
:0:;t
¼, ; :
_ ;;£tzt!ifj
>
~
54
Technische
Beschre.
i bung
Technical description
TeXHM'leCKOe onMcaHMe
9. 4
Information messages
Briej description
(i
iine with approx. 40 characters
possibie;
Response
'
Possible cause
- - - - -
- - - - - - -
-
'
'
' '
102:
Position the tubing set again
Last sensor test more than 24 h ago, deviation in pressure values
Remove the tubing cartridge briefly and then start the pump
again.
150:
Pump
stopped
Device
f~nction interrupted, pump
will
need
to be re-activated
if
error message
is
Communication or pressure measurement disrupted
automatically reset.
180:
Paused
Transient discrepancy between redundant pressure measurement values
Transient sensor
discrepancy,
pump continues automaticatfy
190:
Cartridge detection error
Cartridge detection electronic error
Tum
the
device
off
and on again, contact KARL STORZ Service
if
the
error
reoccurs.
191: Cartrkige locking error
Cartridge locking electronic error
.,
Turn the device off and on agafn, contact KARL STORZ Service if the error reoccurs.
200:
Hardware initialization error
Device
defect
Tum the device
off
and on
again,
contact KARL STORZ Service if the error reoccurs.
· 203:.
C2B error
+
A.
-Self-test: Communication error
Tum the device
off
and on again, contact KARL
STORZ
Service if ttie'error
reoccurs.
20C:
Restart necessary
in <4 h
The device has been
in
continuous operation for more than 20
h.
After 24 h of continuous operation, the pump can no longer be
restarted.
20D: Sensor test overdue
·•
The device has
been
in
continuousqperation for
more
than 24 h.
,>x,u,
Tum device off and on again.
251
:
C 2B error
"iriterriai"communication
error
..
.
...
Tum the device off and on again, contact KARL STORZ Service
if
the error reoccurs
.
252:
Electronics error
Device function
interrupted,
pump will
need
to be re-activated if error message is
Internal communication error
H
automatically reset
254:
Default
restored
File error
Information
message,
work can
continue,
if necessary check the time setting
255:
Electronics error
10 error
Information message, it may be possible to continue work
256:
Date reset
RTC
Battery empty
Information
message,
work can continue
2.
5
8:
USB overcurrent
FE:
USB power too
hiQh
Information
message,
work can
rontinue,
dlsronnect USB connection