Figure 5-4: Connections Of Ba Sensors With Field Wiring Terminals To Pid; Figure 5-5: Using A Pid To Turn On A Pa400W Sounder - ADT FOCUS 200 PLUS Installation And Setup Manual

Commercial fire and burglary security system with scheduling
Hide thumbs Also See for FOCUS 200 PLUS:
Table of Contents

Advertisement

FOCUS 200 PLUS Installation and Setup Guide

Figure 5-4: Connections of BA Sensors with Field Wiring Terminals to PID

5-12
PID BRANCH
CABLE CONNECTOR
HEADER
RECEPTACLE
(NOTE 1)
- 12VDC
BLK
G
1
1
RED
+12VDC
2
2
LOW SIDE
YEL
3
3
BLU
HIGH SIDE
4
4
OR GRN
5
6
(NOTE 2)
EOL RESISTOR
IN PID (NOTE 3)
(A) WIRING DIAGRAM FOR TYPICAL SYSTEM-POWERED BA SENSOR
PID BRANCH
CABLE CONNECTOR
TO SEPARATE
HEADER
RECEPTACLE
POWER SOURCE
(NOTE 1)
G
1
2
BLK
LOW SIDE FEED
3
1
RED
HIGH SIDE FEED
4
2
YEL
LOW SIDE RETURN
5
3
BLU
HIGH SIDE RETURN
6
4
OR GRN
EOL RESISTOR
ON PID BOARD
(B) WIRING DIAGRAM FOR TYPICAL INDEPENDENTLY POWERED BA SENSOR
NOTES:
1. LETTER "G" ON PRINTED WIRING BOARD INDICATES PIN 1 OF HEADER.
2. RECEPTACLE POSITION ON HEADER INDICATES A SYSTEM-POWERED SENSOR.
3. EOL RESISTOR IN PID IS NOT USED FOR SYSTEM-POWERED SENSOR.
4. EOL RESISTOR IS ORDERED SEPARATELY FOR SYSTEM-POWERED SENSOR.
5. ADD JUMPER BETWEEN TA AND AL RELAY CONTACTS AS SHOWN.
6. TAMPER CONTACT IS WIRED ELECTRICALLY AHEAD OF ALARM CONTACT.
7. 6468 BRANCH CABLE CAN BE USED IN PLENUMS.
PID CABLE
CONNECTOR
HEADER
RECEPTACLE
( )
1
1
(+)
2
2
3
3
4
4
5
6
NOTES:
1. MAXIMUM CURRENT TO SOUNDER = 85mA.
2. PROGRAM PID AS COPID POINT, SELECTING
DESIRED FUNCTION THAT WILL CAUSE SOUNDER
TO TURN ON (e.g. BA FIXED, FA, SUPERVISORY).

Figure 5-5: Using a PID to Turn On a PA400W Sounder

(NOTE 6)
TA
AL
+
(NOTE 5)
3010 OHM, 1%, 1/2 W
(SCN 975305) (NOTE 4)
D6441-4 CABLE OR 36468
BRANCH CABLE (NOTE 7)
(NOTE 6)
TA
+
BA SENSOR
TERMINALS
{
(NOTE 5)
D6441-4 CABLE OR 36468
BRANCH CABLE (NOTE 7)
( )
(NOTE 1)
(+)
PA400W
SOUNDER
(INDOOR)
RESISTOR
AL