Programming The System Communication Options - ADT FOCUS 200 PLUS Installation And Setup Manual

Commercial fire and burglary security system with scheduling
Hide thumbs Also See for FOCUS 200 PLUS:
Table of Contents

Advertisement

Signal
Output Trouble
Output Restore
Start BA Test
End BA Test
Start FA Test
End FA Test
Start SPV Test
End SPV Test
AC Fail
Low Battery (4)
Telco Line Trouble (4)
Interprocessor Communication Trouble (4)
Start DLL Process
End DLL Process
Abort DLL Process
DLL Interrupted
DLL Time Limit Exceeded
DLL Comm. Fail
Notes:
1. Signals are transmitted in ADT version of Security Industry Association (SIA) format and include time and date.
2. "Yes" indicates signal is also applicable to SANS service.
3. Signal includes data that identifies the person performing the operation.
4. Signal is cleared when condition is restored.
5. BA points will be automatically unbypassed when the BA group is opened.
6. Untyped designation is used for the following points: BA Keyswitch, BA Janitor Keyswitch, BA End Delay, BA Blocklock, and
Remote Power Supply.

Programming the System Communication Options

To program for system communication, see the Programming section.
SANS (2)
Significance
Yes
Trouble at a SIM output point (e.g., comm fail).
Yes
Trouble has been restored.
Yes
Walk test of BA points has started.
Yes
Walk test of BA points has ended.
Yes
Walk test of FA points has started.
Yes
Walk test of FA points has ended.
Yes
Walk test of supervisory points has started.
Yes
Walk test of supervisory points has ended.
System Self-Supervisory Signals
Yes
Signal initiated after loss of AC power for 4 hours. May be sent with a BA
trouble (Day Set) or entry alarm (Nite Set).
Yes
AC power has failed and standby battery is sensed as being low. May be
sent with a BA trouble or entry alarm.
Yes
Telco line problem; or, if immediately followed by a restoration, it signals
that problem on telco line has been cleared.
Yes
Problem in communication link between communicator module and control
unit microprocessors.
Downline Loading Signals
Yes
Signals that the downline loading (DLL) process with the service terminal
unit has started upon receipt of a Contact Service Terminal command from
the service terminal unit.
Yes
Signals that DLL process has been completed.
Yes
Signals that the DLL process has been aborted. Signal is initiated if
communicator loses contact with service terminal.
Yes
Signals that communication with the service terminal unit has been
interrupted due to alarm condition.
Yes
Signals that the downline loading (DLL) time limit has been exceeded
during communication with the service terminal unit.
Yes
Signals that control unit has failed in three attempts to establish
communication with the service terminal unit.
Section 7 – System Communication
7-11