Option
Cancel Date
BA Group
Control
Access Capability
Person can open and
Inside or
access any time.
Schedule
Same as above, but an
irregular event is
Schedule
flagged for access
outside of schedule
(PVF).
Schedule
Person can open and
Schedule
access, but only within
schedule.
Schedule (2)
Person cannot open, but
can access within
Schedule
schedule.
Schedule (2)
Person cannot gain
Inside or
access at any time.
Schedule
1.
Nothing will be logged or printed if the Log Option = N. Selectable at each reader.
2.
Access can be granted by establishing a temporary schedule.
3.
An access Level of "0" allows users to open and access all BA groups outside of the scheduled opening time without initiating an irregular opening
(normal opening signal to CCC) or irregular access (no signal to CCC).
Table of Privileges
The following table explains the 9 privilege levels available for each user. Privilege levels 1 through 5
apply to users with an operating panel code only.
Level
0
1
2
3
Function
A date can be assigned for temporary users of the system, after which their
card/key or operating panel code will become invalid.
Note: If an RF button is linked to a user code, when the user code cancel date
expires the link is severed. Entering a new cancel date does not re-establish
the link to the RF button.
This serves to identify the number of each BA group within the access-
controlled area, and it is used in conjunction with the BA Group Level
(described above) that is assigned to each person who will have a coded
card/key. In this way, the control unit can determine whether a person's
card/key can be used to gain access to the BA group(s) associated with a given
card/key reader:
If the associated BA groups are Off, any persons having a "C," "O," or "I"
level of access to these groups will be allowed to enter. All other persons
("-" level) will be locked out.
If the associated BA groups are On, only persons with an "I" or "O" level
of access to these groups will be allowed to enter; persons with a "C" or "-"
level will be locked out.
Table of Access Capability
Time
Condition of
BA Group(s)
On
Outside
Off
Inside
On
Off
Outside
On
Off
On
Inside
Off
Outside
On
Off
Inside
On
Off
Outside
On
Off
On
Outside
Off
Privilege
Ability to open and access all BA groups outside of the scheduled opening time without
initiating an irregular opening (open signal to CCC) or irregular access (no signal to CCC).
Ability to bypass and unbypass BA points, and ability to bypass VVS sensors.
Ability to change temporary schedules and change closing times, and ability to change real
time by up to 5 minutes per day.
Ability to change permanent schedules, make unlimited changes in real time, and to
conduct FA sensor test.
Access Action
CCC Signal
Open and Access
Opening
Access
No Signal
Open and Access
Opening
Access
No Signal
Open and Access
Irregular Opening
(PVF)
Access
No Signal
Open and Access
Opening
Access
No Signal
No Access
No Signal
No Access
No Signal
No Access
No Signal
Access
No Signal
No Access
No Signal
No Access
No Signal
No Access
No Signal
No Access
No Signal
Section 10 – Access Control
Log and Print
Programming Required
Opening
BA Group Level = I
Access (1)
Access Level 0 = Y (3)
Opening
BA Group Level = I
Access (1)
Access Level 0 = N (3)
Irregular
PVF = Y
Opening
Irregular Access
Open and Access
BA Group Level = O
Access (1)
Access Level 0 = N (3)
No Access
No Access
No Access
BA Group Level = C
Access (1)
Access Level 0 = N (3)
No Access
No Access
No Access
BA Group Level = —
No Access
plus
plus
plus
plus
plus
10-17