Table Of Ccc Signaling - ADT FOCUS 200 PLUS Installation And Setup Manual

Commercial fire and burglary security system with scheduling
Hide thumbs Also See for FOCUS 200 PLUS:
Table of Contents

Advertisement

FOCUS 200 PLUS Installation and Setup Guide
Signal
BA (#) Day Set (3)
BA (#) Nite Set (3)
Burglar Alarm (Point #) (4)
Burglar Alarm Bypass (Point #) (3)
Burglar Alarm Unbypass (Point #) (3)
Burglar Alarm Trouble
Holdup Alarm (Point #) (4)
Holdup Alarm Bypass (Point #) (3)
Holdup Alarm Unbypass (Point #) (3)
Holdup Alarm Trouble (Point #) (4)
Supervisory Alarm (Point #) (4)
Supervisory Bypass (Point #) (3)
Supervisory Unbypass (Point #) (3)
Supervisory Trouble (Point #) (4)
Fire Alarm (Point #) (4)
Fire Alarm Bypass (Point #) (3)
Fire Alarm Unbypass (Point #) (3)
Fire Alarm Trouble (Point #) (4)
Untyped Alarm (Point #) (4,6)
Untyped Bypass (Point #) (3,6)
Untyped Unbypass (Point #) (3,6)
Untyped Trouble (Point #) (4,6)
Cabinet Tamper Alarm (4)
Operating Panel Tamper Alarm (4)
Printer Interface Tamper Alarm (4)
ADT On Premises (3)
ADT Off Premises (3)
Janitor On Premises
Janitor Off Premises
BA Group (#) Closing Trouble (3)
BA Group (#) Exit Fail
BA Group (#) Bypass (3)
BA Group (#) No Close
BA Group (#) Change Closing Time (3)
BA Group (#) Irregular Opening (3)
Dialer Test
7-10

Table of CCC Signaling

SANS (2)
Significance
No
BA group (#) turned to Protection Off condition.
No
BA group (#) turned to Protection On condition.
Yes
BA alarm at Point (#).
Yes
BA Point (#) has been bypassed.
Yes
BA Point (#) has been unbypassed.
Yes
BA trouble at Point (#). Typically indicates open in PID loop, PID comm
fail, or tamper.
Yes
Holdup alarm at Point (#).
Yes
Holdup alarm Point (#) has been bypassed.
Yes
Holdup alarm Point (#) has been unbypassed.
Yes
Holdup trouble at Point (#). Typically indicates open in PID loop, PID
Comm fail, or tamper.
Yes
Supervisory alarm at Point (#).
Yes
Supervisory Point(s) has been bypassed.
Yes
Supervisory Point (#) has been unbypassed.
Yes
Trouble at supervisory Point (#). Typically indicates open in PID loop, PID
comm fail, or tamper.
Yes
Fire alarm at Point (#).
Yes
Fire alarm Point (#) has been bypassed.
Yes
Fire alarm Point (#) has been unbypassed.
Yes
Trouble at fire alarm Point (#). Typically indicates open in PID loop, PID
comm fail, or tamper.
Yes
Untyped alarm at Point (#).
Yes
Untyped Point (#) has been bypassed.
Yes
Untyped Point (#) has been unbypassed.
Yes
Trouble at Untyped Point (#). Typically indicates open in PID loop, PID
comm fail, or tamper.
Yes
Cabinet tamper has operated.
Yes
Operating panel tamper has operated.
Yes
Printer interface unit tamper has operated.
Yes
Signals entry of ADT service code at operating panel; system is in service
mode.
Yes
Signals entry of Off Premises command at operating panel to terminate
service mode.
Yes
Key inserted in Janitor keyswitch.
Yes
Key removed from Janitor keyswitch.
Yes
One or more BA protection points in BA group (#) are in alarm after
expiration of exit delay.
No
Customer did not exit after turning on protection in BA group (#).
No
Protection has been turned on with BA point(s) bypassed in BA group (#).
No
Protection not closed at the end of closing timer timeout at BA group (#).
No
Close time of BA group (#) has been temporarily changed at an operating
panel.
No
Alarm due to someone turning a BA group off outside of the scheduled
open period, without having the privilege to do so. The irregular opening
and user ID number are transmitted. (Used with ACS service only.)
Yes
Transmitted once upon initialization of control unit, again after 12 hours
have elapsed (as programmed), and thereafter as programmed. Serves to
verify operation of dialing circuitry and integrity of telco line.